美國福祿克FLUKE5142-molbox RFM Gas Flow Calibrator Kits南通-揚(yáng)州-上海-滁州-內(nèi)蒙古-新疆有銷售鐵嶺-盤錦-湛江-蕭山-遼寧-淄博-寧夏-綿陽-云南-朝陽-陜西-青海-北海-唐山-吉林-.北京亦莊開發(fā)區(qū)-正規(guī)銷售處天津?yàn)I海開發(fā)區(qū)-秦皇島經(jīng)濟(jì)開發(fā)區(qū)-太原經(jīng)濟(jì)開發(fā)區(qū)-官方授權(quán)代理商呼和浩特經(jīng)濟(jì)開發(fā)區(qū)-沈陽經(jīng)濟(jì)開發(fā)區(qū)-營口經(jīng)濟(jì)開發(fā)區(qū)-大連經(jīng)濟(jì)開發(fā)區(qū)-長春經(jīng)濟(jì)開發(fā)區(qū)-哈爾濱經(jīng)濟(jì)開發(fā)區(qū)-虹橋經(jīng)濟(jì)開發(fā)區(qū)-漕河涇開發(fā)區(qū)-連云港開發(fā)區(qū)-南通開發(fā)區(qū)-昆山開發(fā)區(qū)-南京開發(fā)區(qū)售后維修聯(lián)系方式-沈陽-長春-常州-連云港-淮安-淮陰-鹽城-揚(yáng)州-徐州-宜興-江陰-官方網(wǎng)站-杭州開發(fā)區(qū)-蕭山開發(fā)區(qū)-溫州開發(fā)區(qū)-價(jià)格寧波開發(fā)區(qū)-蕪湖開發(fā)區(qū)-合肥開發(fā)區(qū)-福州開發(fā)區(qū)-福清融僑開發(fā)區(qū)-東山開發(fā)區(qū)-南昌開發(fā)區(qū)-威海開發(fā)區(qū)-煙臺(tái)開發(fā)區(qū)-青島開發(fā)區(qū)-鄭州開發(fā)區(qū)-北京-上海-淮安-連云港-昆山-浙江-廣東-河南-杭州-鄭州-廣州-深圳-佛山-惠州-廈門-汕頭-臺(tái)灣-香港-天津-西安-寶雞-杭州-溫州-常州-如何使用操作視頻杭州-嘉興-湖州-秦皇島-邯鄲-邢臺(tái)-保定-張家口-承德-廊坊-呼和浩特-包頭-鞍山-大慶-錦州-蘇州-昆山原理-無錫-鎮(zhèn)江-武漢開發(fā)區(qū)-長沙開發(fā)區(qū)-蘿崗區(qū)開發(fā)區(qū)-廣州南沙開發(fā)區(qū)-惠州大亞灣開發(fā)區(qū)-湛江開發(fā)區(qū)-南寧開發(fā)區(qū)-價(jià)格重慶開發(fā)區(qū)-使用說明書成都開發(fā)區(qū)-貴陽開發(fā)區(qū)-昆明開發(fā)區(qū)-拉薩開發(fā)區(qū)-西安開發(fā)區(qū)-蘭州開發(fā)區(qū)-西寧開發(fā)區(qū)-銀川開發(fā)區(qū)-烏魯木齊開發(fā)區(qū)-石河子開發(fā)區(qū)-使用說明書金橋出口加工區(qū)-蘇州工業(yè)園-哈爾濱哪家公司的優(yōu)惠些-濟(jì)南-武漢-廣州-南寧-成都-西安-大連-寧波-廈門-青島-深圳生產(chǎn)廠家-多少錢寧波大榭開發(fā)區(qū)-廈門海滄投資區(qū)-海南洋浦開發(fā)區(qū)無錫-蘇州-南京-鎮(zhèn)江-揚(yáng)州-南通-合肥-徐州-常熟-石家莊-太原進(jìn)口品牌-呼和浩特-沈陽-長春-哈爾濱-南京-合肥-福州-南昌-濟(jì)南-鄭州-武漢-長沙-廣州-南寧-海口-成都-貴陽-昆明-拉薩-西安-蘭州-西寧-銀川-烏魯木齊-杭州
當(dāng)前位置:首頁 > 產(chǎn)品中心 > 電子電工 > 計(jì)量校準(zhǔn)
molbox RFM Gas Flow Calibrator Kits
品 牌:美國福祿克FLUKE
型 號(hào):5142
市場(chǎng)價(jià):
促銷價(jià):
主要技術(shù)指標(biāo):Maximum working measurement line pressure  600 kPa (87 psi) absolute

High end gas flow calibration made simple

Fluke Calibration 5141, 5142 and 5144 molbox RFM gas flow calibrator kits feature molbox RFM and molbloc-L configurations optimized to cover a very wide workload combined with molstic-L and other interconnect hardware needed for a complete calibration system. Simply supply 90 psi of pure N2 or air to the system. An included regulator delivers a stable regulated flow to the molbloc. Downstream of the molbloc, an included metering valve allows you to regulate the mass flow value required for the DUT. It’s that simple; supply 90 psi gas upstream, tare the reading, and adjust the fine metering valve to deliver the desired mass flow rate with an accuracy of ± 0.5 % of reading. Fluke Calibration gas flow calibrator kits eliminate complication, but don’t compromise molbox/molbloc best in class performance.

·          Flow ranges cover from 1 sccm to 50 slm

·         ± 0.5 % of reading total one-year accuracy

·         Measures mass and volume flow with user settable reference pressure and temperature conditions

·         Reference standard is upstream of the device under test, eliminating cross contamination and expensive damage to the flow elements

·         Integrated gas flow regulation and adjustment hardware

·         Expandable to over 5000 slm with additional molbloc flow elements and control hardware

·         Includes traceable calibration for operation in N2 and Air, with corrections for other gases

·         Gas supply and test adapters included for 1/4 in tube, 1/4 in NPT and 1/4 in BSP

·         Includes advanced functions such as totalize, average, hi/lo, deviation, on-board purge, leak test and tare, available from the front control panel or by RS-232 and IEEE-488 remote interfaces

A new standard in high end gas flow calibration

Fluke Calibration revolutionized high end gas flow calibration with the introduction of molbox/ molbloc mass flow standards. molbox/molbloc systems have replaced large, inflexible, error prone volumetric piston provers and bell provers with a compact, easy to use, versatile digital standard. molbox/molbloc systems are the standard of choice for high end calibration labs and mass flow device manufacturers around the world. Improvements offered by molbox/molbloc include:

·         True mass flow calibration and traceability— no corrections from volumetric to mass

·         Real-time digital mass flow indication, loaded with features—easily automated

·         No moving parts—uninterrupted gas flow measurement, no fluctuations from piston stroke

·         Flexibility to be positioned upstream or downstream— can calibrate at many line pressures

·         Modular components allows future upgrade and expansion

·         Very wide range with small footprint—no flow straightening hardware required

 Whether your requirement is manual calibration of a simple variable area flow meter (rotameter) or fully automated calibration of a mass flow controller (MFC), molbox/molbloc systems offer the ideal solution. A molbox RFM with one or more molbloc flow elements can cover a wide range of flow calibration devices with total one-year measurement uncertainty of ± 0.5 % of reading. If your needs change, molbloc flow elements can be added, with models covering flows from 1 sccm to over 5000 slm (175 scfm). If better measurement uncertainty is needed, the same flow elements can be used with molbox1+ to achieve accuracy as good as ± 0.125 % of reading.

Measurement specifications

Gas calibration included

Nitrogen (N2), Air

Maximum working measurement line pressure

600 kPa (87 psi) absolute

Measurement range

<1sccm to 50 slm, depending on model. Flow ranges depend on test gas. Ranged indicated for N2 and Air.

 

型號(hào)

描述

5141-100

molbox RFM, molbloc 5E1-L 10 to 100 sccm

Included:

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 5E1-L laminar flow element 

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

5141-1K

molbox RFM, molbloc 5E2-L 100 to 1,000 sccm

Included: 

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 5E2-L laminar flow element 

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

5141-10K

molbox RFM, molbloc 5E3-L 1 to 10 slm

Included: 

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 5E3-L laminar flow element

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

5141-50K

molbox RFM, molbloc 3E4-L 5 to 50 slm

Included: 

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 3E4-L laminar flow element 

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

5142-1K

molbox RFM-M, molbloc 5E2-L 10 to 1,000 sccm

Included: 

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 5E2-L laminar flow element 

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

5142-10K

molbox RFM-M, molbloc 5E3-L 0.1 to 10 slm

Included: 

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 5E3-L laminar flow element 

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

5142-50K

molbox RFM-M, molbloc 3E4-L 0.5 to 50 slm

Included: 

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 3E4-L laminar flow element 

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

5144-50K

molbox RFM-M, molblocs 5E2-L and 3E4-L10 sccm to 50 slm

Included:

·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

·        molbloc 5E2-L and 3E4-L laminar flow elements

·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

 

,,